TR4 Report is a mobile application that collects recorded data from TR4 via Bluetooth and generates a PDF report for the specified period. The report can then be printed, saved or shared via email or apps that can handle PDF files.
Compatible OS: Android OS, iOS
For compatible versions, please refer to the Software page of our website.
T&D Website > Software/Apps > TR4 Report
Upon registration, the logger will start recording with the following settings. Note that all stored data will be deleted when a new recording session is started.
Rec Interval: 1 min.
Rec Mode: Endless
Open the TR4 Report app on your device.
The app scans for nearby devices via Bluetooth and displays them in a list with the device name and serial number. If the device name has not been set, [Model_serial number] will appear.
Tap on a device to open the Device Registration screen.
Enter the registration code*.
Most of the setting items can also be set from the Device Settings later.
*The registration code can be found on the supplied registration code label.
Tap [Apply] to register the device; it will be added to the Registered Devices list in the HOME Screen.
If you change your smartphone/tablet, it is necessary to perform device registration again.
A list broken into two sections will appear showing all of the nearby devices within communication range and the devices that have been registered to the app.
To communicate with nearby devices, tap on the device in the list and perform the Device Registration.
App Version Info
Help (this document)
Support Info (site link)
You can sort the device list or delete the registered device here.
The registered devices are listed by the device name and serial number, along with the battery icon.
Tapping on the device in the list will open the Device Settings screen.
Tapping the button will switch between [Begin] and [End].
Tap [Begin] to set the start-point of the report, and [End] to set the end-point.
Tap to open the Report Settings screen.
Open the Device Settings by tapping the device name in the Registered Devices list on the HOME screen.
Change the desired settings and tap [Apply].
To return to the HOME screen, tap the arrow () at the top left of the screen.
Each name can contain up to 16 alphanumeric characters
(¥/:;,*?"<>|&' are not allowed)
Set the temperature unit to be used in the report.
If you wish to set the upper limit and/or lower limit, enter the limit value(s).
Tap to apply the settings.
In the HOME screen tap [Edit].
Press and hold () and then drag to the desired location.
When sorting is finished, tap [Done].
In the HOME screen tap [Edit].
Tap () and then [Delete] to remove the device from the registered list.
Tap [Done] to return to the previous screen.
This is an operation example of creating reports for multiple devices in a shipping container.
Please note that you need to be within Bluetooth range.
When you depart, tap [Begin] for each device to set the start-point of the report.
When you arrive, tap [End] for each device to set the end-point of the report.
Tap [Report] to create a report for the first device.
Enter the title and comments if necessary in the Report Settings. It is also possible to change other settings (MKT, Begin/End time) here.
By tapping [Create], the app will create a PDF report for the specified time period.
Select the desired output option (Print, Email, Save/Share).
Return to the HOME screen using the arrow () at the top left of the screen, and tap [Report] for the next device. Repeat steps 4-5.
Enter the title for the report (up to 30 characters).
The same title will be displayed from the second time; please change if necessary.
Enter comments if necessary (up to 200 characters).
The same comments will be displayed from the second time; please change if necessary.
By turning on, the mean kinetic temperature (MKT) will be automatically calculated when creating a report.
The date and time when the Begin/End button was tapped is displayed.
Shows the upper/lower limit value(s) set in the Device Registration or Device Settings.
Tap to create a PDF report.
Mean Kinetic Temperature (MKT) is a way of expressing the effect of temperature fluctuations during storage or transit of perishable goods.
EX:
Shows the report title (if set in the Report Settings), time range (Begin-End times), number of readings, recording interval and mode.
Shows device name, model, and serial number.
Determines and displays whether the upper or lower limit has been exceeded during the specified time range.
This will be blank if no limit has been set.
Alert: The limit has been exceeded
OK: The limit has not been exceeded
Shows the upper and lower limit values* set in the Report Settings (Also shown by the colored lines on the graph.)
Shows the highest/lowest/average readings in the time range, total time of alarm* and MKT (Mean Kinetic Temperature)*.
* Hyphens (----) mean no setting
The file name will be created automatically using the following format:
device name (serial number)_date/time.pdf
Shows the comments entered in the Report Settings.
Select the output option for the generated report.
If you exit the app or go back to the previous screen without saving the report, data will be lost.
Tap here to print the report to any compatible printer nearby.
Tap here to send the report as an attachment via email.
Tap here to open the Save/Share menu for your OS.