| FCC model / CE model | RTR-501/501L |
RTR-502/502L |
RTR-503/503L |
|
|---|---|---|---|---|
| Measurement Channels | Temperature 1ch (Internal) | Temperature 1ch (External) | Temperature 1ch, Humidity 1ch (External) | |
| Sensor | Thermistor | Thermistor | Thermistor | Polymer Resistance |
| Measurement Units | °C, °F | °C, °F | °C, °F | % |
| Measurement Range | -40 to 80°C | -60 to 155°C | 0 to 55°C | 10 to 95%RH |
| Accuracy | Avg±0.5°C | Avg±0.3°C [-20 to 80°C] Avg±0.5°C [-40 to -20°C /80 to 110°C] Avg±1.0°C [-60 to -40°C /110 to 155°C] |
Avg±0.3°C | ±5%RH [at 25°C and 50%RH] |
| Measurement Resolution | 0.1°C | 0.1°C | 0.1°C | 1%RH |
| Responsiveness | Thermal Time Constant: Approx. 15 min. Approx. 25 min.(L Type) Response Time (90%): Approx. 35 min. Approx. 47 min.(L Type) |
Thermal Time Constant: Approx. 30 sec. (in air) Approx. 4 sec. (in agitated water) Response Time (90%): Approx. 80 sec. (in air) Approx. 7 sec. (in agitated water) |
Response Time (90%): Approx. 7 min. |
|
| Logging Capacity | 16,000 readings | 8,000 data sets (One data set consists of readings for multiple channels.) | ||
| Recording Intervals | Select from 15 choices: 1,2,5,10,15,20,30 sec. or 1,2,5,10,15,20,30,60 min. |
|||
| Recording Mode (*1) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|||
| LCD Display Items | Measurements (alternating display for multiple channel devices), Battery Life Warning, etc. | |||
| Communication Interfaces | Wireless Communication (Short Range Radio Communication): ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) Optical Communication |
|||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | |||
| Power | Lithium Battery: LS14250(*2) x 1 L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*3) External Power Adaptor Kit (RTR-500A1: sold separately) |
|||
| Battery Life (*4) | About 10 months L Type: About 4 years |
|||
| Dimensions | H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm |
|||
| Weight | Approx. 56g L Type: approx. 109g (including battery / excluding sensor) |
|||
| Operating Environment | -40 to 80°C (-30 to 80°C during wireless communications) | |||
| Waterproof Capacity | IP67: immersion proof | IP64: Splash proof (rated for use in daily life) (*5) | IP64: Splash proof (rated for use in daily life) (*5) Note: Sensor is not water resistant. |
|
| Accessories | - | Temperature Sensor (TR-5106) | Temperature/Humidity Sensor (TR-3310) | |
| Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Strap, User's Manual (Warranty Included) | ||||
| Compatible Base Units | RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM | |||
|
||||
| FCC model / CE model | RTR-505-TC/ 505-TCL |
RTR-505-Pt/ 505-PtL |
RTR-505-V/ 505-VL |
RTR-505-mA/ 505-mAL |
RTR-505-P/ 505-PL |
|
|---|---|---|---|---|---|---|
| Measurement Channels | Temperature 1ch | Temperature 1ch | Voltage 1ch | 4-20mA 1ch | Pulse Count 1ch | |
| Sensor | Thermocouple: Type K, J, T, S |
Pt100, Pt1000 (3-wire) |
- | - | - | |
| Measurement Units | °C, °F | °C, °F | V, mV | mA | P | |
| Measurement Range | -199 to 1700°C | -199 to 600°C | 0 to 22V | 0 to 20mA (Operational up to 40mA) |
Input Signal: ・Non-voltage Contact Input ・Voltage Input (0 to 27 V) Detection Voltage Lo: 0.5 V or less Hi: 2.5V or more Input Impedance: Approx. 100 KΩ pull up Chattering Filter: ON: 15 Hz or less OFF: 3.5 kHz or less Maximum Count 61,439 / Recording Interval |
|
| Accuracy(*1) | Thermocouple Measurement ±(0.3°C + 0.3 % rdg) [Type K, J, T] ±(1°C + 0.3 % rdg) [Type S] Cold Junction Compensation ±0.3°C [10 to 40°C] ±0.5°C [-40 to 10°C / 40 to 80°C] |
±(0.3°C + 0.3 % rdg) [10 to 40°C] ±(0.5°C + 0.3 % rdg) [-40 to 10°C / 40 to 80°C] |
±(0.5 mV + 0.3 % rdg) [10 to 40°C] ±(1 mV + 0.5 % rdg) [-40 to 10°C / 40 to 80°C] |
±(0.05 mA + 0.3 % rdg) [10 to 40°C] ±(0.1mA + 0.3 % rdg) [-40 to 10°C / 40 to 80°C] |
||
| Note: The above temperatures [__°C] are for the operating environment of the Input Module. | ||||||
| Measurement Resolution |
Type K, J, T : 0.1 °C Type S : Approx. 0.2 °C |
0.1 °C | up to 400mV: at 0.1mV, up to 800mV: at 0.2mV, up to 999mV: at 0.4mV, up to 3.2V: at 1mV, up to 6.5V: at 2mV, up to 9.999V: at 4mV, up to 22V: at 10mV |
0.01 mA | ||
| Module Specifications |
TCM-3010 | PTM-3010 | VIM-3010 | AIM-3010 | PIC-3150 | |
| Logging Capacity | 16,000 readings | |||||
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |||||
| Recording Mode(*2) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|||||
| LCD Display Items | Measurements (alternating display for multiple channel devices), Battery Life Warning, etc. | |||||
| Communication Interfaces | Wireless Communication (Short Range Radio Communication): ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) Optical Communication (proprietary protocol) |
|||||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | |||||
| Power | Lithium Battery: LS14250(*3) x 1 L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*4) External Power Adaptor Kit (RTR-500A1: sold separately) |
|||||
| Battery Life(*5) | About 10 months L Type: About 4 years |
|||||
| Dimensions | H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm |
|||||
| Weight | Approx. 56g L Type: approx. 109g (including battery / excluding sensor) |
|||||
| Operating Environment | -40 to 80°C (-30 to 80°C during wireless communication) | |||||
| Waterproof Capacity(*6) | IP64: Splash proof (rated for use in daily life) Note: Sensor is not water resistant. |
|||||
| Accessories | Input Module (TCM-3010) |
Input Module (PTM-3010) |
Input Module (VIM-3010) |
Input Module (AIM-3010) |
Input Module (PIC-3150) |
|
| Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Strap, User's Manual (Warranty Included) | ||||||
| Compatible Base Units | RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM | RTR-500, RTR-500NW/500AW, RTR-500DC | ||||
|
||||||
| FCC model / CE model | RTR-507/507L |
||||
|---|---|---|---|---|---|
| Measurement Channels | Temperature 1ch, Humidity 1ch (External) | ||||
| Sensor | Platinum Resistance | Electrostatic Capacitance | |||
| Measurement Range | -30 to 80℃ | 0 to 99%RH | |||
| Accuracy | ±0.3℃ [at 0 to 50℃] ±0.5℃ [at all other temperatures] | 2.5 %RH [at 25℃, 10 to 85 %RH] 4.0 %RH [at 25℃, 0 to 10 or 85 to 99 %RH] At temperatures other than 25℃ and ≥ 0℃, add 0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower (*1) |
|||
| Measurement Resolution | 0.1℃ | 0.1 %RH | |||
| Responsiveness | Response Time (90%): Approx. 7 min. | Response Time (90%): Approx. 20 sec. | |||
| Logging Capacity | 8000 data sets (One data set consists of readings for both temperature and humidity.) | ||||
| Recording Intervals | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30sec. or 1, 2, 5, 10, 15, 20, 30, 60min. |
||||
| Recording Mode (*2) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
||||
| LCD Display Items | Measurements (alternating display for multiple channel devices), Battery Life Warning, etc. | ||||
| Communication Interfaces | Wireless Communication (Short Range Radio Communication): ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) Optical Communication (proprietary protocol) |
||||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | ||||
| Power | Lithium Battery: LS14250(*3) L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*4) | ||||
| Battery Life (*5) | About 10 months L Type: About 4 years |
||||
| Dimensions | H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm |
||||
| Weight | Approx. 56g L Type: approx. 109g (including battery / excluding sensor) |
||||
| Operating Environment | -40 to 80°C (-10 to 80°C during wireless communication)(*6) | ||||
| Waterproof Capacity | IP64: Splash proof (rated for use in daily life)(*7) Note: Sensor is not water resistant. | ||||
| Accessories | Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Temperature/Humidity Sensor (HHB-3101), Strap, User's Manual (Warranty Included) | ||||
| Compatible Base Units | RTR-500, RTR-500NW/500AW, RTR-500DC | ||||
|
|||||
| Product | RTR-574 | RTR-574-H | ||
|---|---|---|---|---|
| Temperature/Humidity Sensor (External) | THA-3151 | HHA-3151(High-Precision Type) | ||
| Thermistor | Polymer Resistance | Platinum Resistance | Electrostatic Capacitance | |
| Measurement Channels | Temperature 1ch | Humidity 1ch | Temperature 1ch | Humidity 1ch |
| Units of Measurement | °C, °F | %RH | °C, °F | %RH |
| Measurement Range | 0 to 55 °C | 10 to 95 %RH | -30 to 80 °C | 0 to 99 %RH |
| Accuracy | ±0.5 °C | ±5 %RH [at 25 °C, 50 %RH] | ±0.3°C [0 to 50 °C) ±0.5°C [all other temperatures] | ±2.5 %RH[at 25 °C, 10 to 85 %RH] ±4.0 %RH[at 25 °C, 0 to 10 % or 85 to 99 %RH] At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*1) |
| Measurement Resolution | 0.1 °C | 1 %RH | 0.1 °C | 0.1 %RH |
| Responsiveness | Response Time(90%): Approx. 7 min. |
Response Time(90%): Approx. 7 min. |
Response Time(90%): Approx. 20 sec. |
|
| Illuminance/UV Sensor (External) | ISA-3151 | |||
| Measurement Channels | Illuminance: 1ch UV intensity: 1ch |
|||
| Units of Measurement | Illuminance: lx, Klx UV intensity: mW/cm2 |
|||
| Measurement Range | Illuminance: 0 lx to 130 Klx UV Intensity: 0 to 30 mW/cm2 |
|||
| Units of Cumulative Measurement | Cumulative Illuminance: lxh, Klxh, Mlxh Cumulative amount of UV Light: mW/cm2, W/cm2 |
|||
| Display Range of Cumulative Measurement |
Illuminance: 0 lxh to 90 Mlxh UV Intensity: 0 mW to 62 W/cm2h |
|||
| Accuracy | Illuminance: 10 lx to 100 Klx:±5 % [at 25°C, 50 %RH] UV Intensity: 0.1 to 30 mW/cm2:±5 % [at 25°C, 50 %RH] (*2) |
|||
| Relative Spectral Response | Illuminance: Approximated to the CIE standard response function V (λ ) UV Intensity: 260 to 400 nm |
|||
| Measurement Resolution | Illuminance: Minimum of 0.01 lx UV Intensity: Minimum of 0.001 mW/cm2 |
|||
| Responsiveness | Response Time(90%): 3 sec. (at recording interval of 1 sec.) 6 sec. (at other intervals) |
|||
| Logging Capacity | 8,000 data sets (One data set consists of readings for all channels in that type of unit.) | |||
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |||
| Recording Mode (*3) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) | |||
| LCD Display Items | Measurements, Battery Life Warning, etc. ・Measurements: Illuminance / UV Intensity / Temperature / Humidity / Cumulative Illuminance / Cumulative amount of UV Light ・Display Pattern: Alternating or Fixed display ・Display Digits: Up to 4 digits |
|||
| Communication Interfaces |
Wireless Communication (Short Range Radio Communication) ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) USB Communication Serial Communication (RS-232C)(*4) |
|||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | |||
| Power | AA Alkaline Battery (LR6) x 1 | |||
| Battery Life (*5) | Approx. 4 months | |||
| Dimensions | H 55 mm x W 78 mm x D 18 mm(excluding protrusions) Antenna Length: 60 mm |
|||
| Weight | About 68 g (including battery, excluding sensor) | |||
| Operating Environment | Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) |
|||
| Accessories | AA alkaline battery (LR6), USB Communication Cable (US-15C), Illuminance/UV Sensor (ISA-3151), Temperature/Humidity Sensor (THA-3151 or HHA-3151), Software (CD-ROM), User's Manual Set (Warranty Included) | |||
| Compatible Base Units | RTR-500, RTR-500NW/500AW, RTR-500DC | |||
|
||||
| Product | RTR-576 | RTR-576-H | ||
|---|---|---|---|---|
| Temperature/Humidity Sensor (External) | THA-3001 | HHA-3151(High-Precision Type) | ||
| Thermistor | Polymer Resistance | Platinum Resistance | Electrostatic Capacitance | |
| Measurement Channels | Temperature 1ch | Humidity 1ch | Temperature 1ch | Humidity 1ch |
| Measurement Range(*1) | 0 to 55 °C | 10 to 95 %RH | -30 to 80 °C | 0 to 99 %RH |
| Accuracy | ±0.5 °C | ±5 %RH [at 25 °C, 50 %RH] | ±0.3°C [at 10 to 50 °C] ±0.5°C [at all other temperatures] |
±2.5 %RH [at 25 °C, 10 to 85 %RH] ±4.0 %RH [at 25 °C, 0 to 10 % or 85 to 99 %RH] At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*2) |
| Measurement Resolution | 0.1 °C | 1 %RH | 0.1 °C | 0.1 %RH |
| Responsiveness | Response Time(90%): Approx. 7 min. |
Response Time(90%): Approx. 7 min. |
Response Time(90%): Approx. 20 sec. |
|
|   | ||||
| CO2 Sensor (Internal) | NDIR | |||
| Measurement Channels | CO2 Concentration 1ch | |||
| Measurement Range | 0 to 9,999 ppm | |||
| Accuracy | ±(50 ppm + 5 % of reading) [at 5,000 ppm or less] (*3) | |||
| Measurement Resolution | Minimum of 1 ppm | |||
| Responsiveness | Response Time (90%): Approx. 1 min. | |||
|   | ||||
| Logging Capacity | 8,000 data sets (One data set consists of readings for all channels in that type of unit.) | |||
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |||
| Recording Mode (*4) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) | |||
| LCD Display Items | Measurements, Battery Level, etc. - Measurements: CO2 concentration, Temperature or Humidity (fixed or alternating display) | |||
| Communication Interfaces | Wireless Communication (Short Range Radio Communication) FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW) ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) USB Communication Serial Communication (RS-232C) (*5) | |||
| Wireless Transmission Range | Approx. 150 meters (500 ft) if direct and unobstructed | |||
| External Alarm Terminal (*6) | Output Terminal: Open Drain Output (Voltage when OFF: DC less than 30V / Current when ON: less than 0.1A / Resistance when ON: about 15Ω) | |||
| Power | AC Adaptor (AD-0638 or AD-0638-C), AA Alkaline Battery (LR6) x 4 | |||
| Battery Life (*7) | Approx. 2 days (batteries only without AC adaptor) | |||
| Dimensions | H 96 mm x W 66 mm x D 46 mm (excluding protrusions and sensor) Antenna Length: 60 mm |
|||
| Weight | Approx. 220 g (including battery, excluding sensor) | |||
| Operating Environment | Temperature: 0 to 45 °C Humidity: 90 %RH or less (no condensation) |
|||
| Accessories | AA Alkaline Battery (LR6) x 4, AC Adaptor (AD-0638 or AD-0638-C), USB Communication Cable (US-15C), Temperature/Humidity Sensor (THA-3001 or HHA-3151), User's Manual Set (Warranty Included) | |||
| Compatible Base Units | RTR-500C, RTR-500NW/500AW, RTR-500DC | |||
|
||||