RTR-500 Series - Wireless Data Logging System

Specifications
FCC model / CE model
RTR-501/501L
RTR-502/502L
RTR-503/503L
Measurement Channels Temperature 1ch (Internal) Temperature 1ch (External) Temperature 1ch, Humidity 1ch (External)
Sensor Thermistor Thermistor Thermistor Polymer Resistance
Measurement Units °C, °F °C, °F °C, °F %
Measurement Range -40 to 80°C -60 to 155°C 0 to 55°C 10 to 95%RH
Accuracy Avg±0.5°C Avg±0.3°C
[-20 to 80°C]
Avg±0.5°C
[-40 to -20°C /80 to 110°C]
Avg±1.0°C
[-60 to -40°C /110 to 155°C]
Avg±0.3°C ±5%RH
[at 25°C and 50%RH]
Measurement Resolution 0.1°C 0.1°C 0.1°C 1%RH
Responsiveness Thermal Time Constant:
Approx. 15 min.
Approx. 25 min.(L Type)

Response Time (90%):
Approx. 35 min.
Approx. 47 min.(L Type)
Thermal Time Constant:
Approx. 30 sec. (in air)
Approx. 4 sec. (in agitated water)

Response Time (90%):
Approx. 80 sec. (in air)
Approx. 7 sec. (in agitated water)
Response Time (90%):
Approx. 7 min.
Logging Capacity 16,000 readings 8,000 data sets (One data set consists of readings for multiple channels.)
Recording Intervals Select from 15 choices:
1,2,5,10,15,20,30 sec. or 1,2,5,10,15,20,30,60 min.
Recording Mode (*1) Endless (Overwrite oldest data when capacity is full)
or One Time (Stop recording when capacity is full)
LCD Display Items Measurements (alternating display for multiple channel devices), Battery Life Warning, etc.
Communication Interfaces Wireless Communication (Short Range Radio Communication):
 ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
 ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
Optical Communication
Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
Power Lithium Battery: LS14250(*2) x 1
L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*3)
External Power Adaptor Kit (RTR-500A1: sold separately)
Battery Life (*4) About 10 months
L Type: About 4 years
Dimensions H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and sensor)
Antenna length: 24 mm
Weight Approx. 56g
L Type: approx. 109g
(including battery / excluding sensor)
Operating Environment -40 to 80°C (-30 to 80°C during wireless communications)
Waterproof Capacity IP67: immersion proof IP64: Splash proof (rated for use in daily life) (*5) IP64: Splash proof (rated for use in daily life) (*5)
Note: Sensor is not water resistant.
Accessories - Temperature Sensor (TR-5106) Temperature/Humidity Sensor (TR-3310)
Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Strap, User's Manual (Warranty Included)
Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM
  • (*1) Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.
  • (*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
  • (*3) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
  • (*4) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way.
  • (*5) This is the waterproof capacity of the data logger with the sensor connected.

FCC model / CE model RTR-505-TC/
505-TCL
RTR-505-Pt/
505-PtL
RTR-505-V/
505-VL
RTR-505-mA/
505-mAL
RTR-505-P/
505-PL
Measurement Channels Temperature 1ch Temperature 1ch Voltage 1ch 4-20mA 1ch Pulse Count 1ch
Sensor Thermocouple:
Type K, J, T, S
Pt100, Pt1000
(3-wire)
- - -
Measurement Units °C, °F °C, °F V, mV mA P
Measurement Range -199 to 1700°C -199 to 600°C 0 to 22V 0 to 20mA
(Operational
up to 40mA)
Input Signal:
・Non-voltage Contact Input
・Voltage Input (0 to 27 V)

Detection Voltage
Lo: 0.5 V or less
Hi: 2.5V or more
Input Impedance:
Approx. 100 KΩ pull up

Chattering Filter:
ON: 15 Hz or less
OFF: 3.5 kHz or less

Maximum Count
61,439 / Recording Interval
Accuracy(*1) Thermocouple Measurement
±(0.3°C + 0.3 % rdg) [Type K, J, T]
±(1°C + 0.3 % rdg) [Type S]

Cold Junction Compensation
±0.3°C [10 to 40°C]
±0.5°C [-40 to 10°C / 40 to 80°C]
±(0.3°C + 0.3 % rdg) [10 to 40°C]
±(0.5°C + 0.3 % rdg) [-40 to 10°C / 40 to 80°C]
±(0.5 mV + 0.3 % rdg) [10 to 40°C]
±(1 mV + 0.5 % rdg) [-40 to 10°C / 40 to 80°C]
±(0.05 mA + 0.3 % rdg) [10 to 40°C]
±(0.1mA + 0.3 % rdg) [-40 to 10°C / 40 to 80°C]
Note: The above temperatures [__°C] are for the operating environment of the Input Module.
Measurement
Resolution
Type K, J, T :
0.1 °C
Type S :
Approx. 0.2 °C
0.1 °C up to 400mV: at 0.1mV,
up to 800mV: at 0.2mV,
up to 999mV: at 0.4mV,
up to 3.2V: at 1mV,
up to 6.5V: at 2mV,
up to 9.999V: at 4mV,
up to 22V: at 10mV
0.01 mA
Module
Specifications
TCM-3010 PTM-3010 VIM-3010 AIM-3010 PIC-3150
Logging Capacity 16,000 readings
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode(*2) Endless (Overwrite oldest data when capacity is full)
or One Time (Stop recording when capacity is full)
LCD Display Items Measurements (alternating display for multiple channel devices), Battery Life Warning, etc.
Communication Interfaces Wireless Communication (Short Range Radio Communication):
 ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
 ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
Optical Communication (proprietary protocol)
Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
Power Lithium Battery: LS14250(*3) x 1
L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*4)
External Power Adaptor Kit (RTR-500A1: sold separately)
Battery Life(*5) About 10 months
L Type: About 4 years
Dimensions H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and sensor)
Antenna length: 24 mm
Weight Approx. 56g
L Type: approx. 109g
(including battery / excluding sensor)
Operating Environment -40 to 80°C (-30 to 80°C during wireless communication)
Waterproof Capacity(*6) IP64: Splash proof (rated for use in daily life)
Note: Sensor is not water resistant.
Accessories Input Module
(TCM-3010)
Input Module
(PTM-3010)
Input Module
(VIM-3010)
Input Module
(AIM-3010)
Input Module
(PIC-3150)
Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Strap, User's Manual (Warranty Included)
Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500GSM RTR-500, RTR-500NW/500AW, RTR-500DC
  • (*1) "rdg" stands for reading.
  • (*2) Only "Endless" is available when using RTR-500W for Windows or RTR-500GSM for Windows.
  • (*3) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
  • (*4) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
  • (*5) Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way.
  • (*6) This is the waterproof capacity of the data logger with the sensor connected.

FCC model / CE model
RTR-507/507L
Measurement Channels Temperature 1ch, Humidity 1ch (External)
Sensor Platinum Resistance Electrostatic Capacitance
Measurement Range -30 to 80℃ 0 to 99%RH
Accuracy ±0.3℃ [at 0 to 50℃] ±0.5℃ [at all other temperatures] 2.5 %RH [at 25℃, 10 to 85 %RH]
4.0 %RH [at 25℃, 0 to 10 or 85 to 99 %RH]
At temperatures other than 25℃ and ≥ 0℃, add 0.1 %RH per degree of difference from 25.
Humidity Hysteresis: ±1.5 %RH or lower (*1)
Measurement Resolution 0.1℃ 0.1 %RH
Responsiveness Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 20 sec.
Logging Capacity 8000 data sets (One data set consists of readings for both temperature and humidity.)
Recording Intervals Select from 15 choices:
1, 2, 5, 10, 15, 20, 30sec. or 1, 2, 5, 10, 15, 20, 30, 60min.
Recording Mode (*2) Endless (Overwrite oldest data when capacity is full)
or One Time (Stop recording when capacity is full)
LCD Display Items Measurements (alternating display for multiple channel devices), Battery Life Warning, etc.
Communication Interfaces Wireless Communication (Short Range Radio Communication):
 ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
 ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
Optical Communication (proprietary protocol)
Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
Power Lithium Battery: LS14250(*3) L Type: Large Capacity Battery Adaptor Kit (RTR-500B1)(*4)
Battery Life (*5) About 10 months
L Type: About 4 years
Dimensions H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and sensor)
Antenna length: 24 mm
Weight Approx. 56g
L Type: approx. 109g
(including battery / excluding sensor)
Operating Environment -40 to 80°C (-10 to 80°C during wireless communication)(*6)
Waterproof Capacity IP64: Splash proof (rated for use in daily life)(*7) Note: Sensor is not water resistant.
Accessories Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR-500B1), Temperature/Humidity Sensor (HHB-3101), Strap, User's Manual (Warranty Included)
Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC
  • (*1) When used in environments where temperature and humidity are over the values of 50℃ 75%, 60℃ 50%, 70℃ 35%, and 80℃ 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
  • (*2) Only "Endless" is available when using RTR-500W for Windows.
  • (*3) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement.
  • (*4) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
  • (*5) Battery life varies depending upon the ambient temperature in which it is used, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
  • (*6) When wireless communication is performed in an environment below -10°C, measurement may fail or may not be accurate.
  • (*7)This is the waterproof capacity of the data logger with the sensor connected.

Product RTR-574 RTR-574-H
Temperature/Humidity Sensor (External) THA-3151 HHA-3151(High-Precision Type)
Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance
Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch
Units of Measurement °C, °F %RH °C, °F %RH
Measurement Range 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH
Accuracy ±0.5 °C ±5 %RH [at 25 °C, 50 %RH] ±0.3°C [0 to 50 °C) ±0.5°C [all other temperatures] ±2.5 %RH[at 25 °C, 10 to 85 %RH] ±4.0 %RH[at 25 °C, 0 to 10 % or 85 to 99 %RH] At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*1)
Measurement Resolution 0.1 °C 1 %RH 0.1 °C 0.1 %RH
Responsiveness Response Time(90%):
Approx. 7 min.
Response Time(90%):
Approx. 7 min.
Response Time(90%):
Approx. 20 sec.
 
Illuminance/UV Sensor (External) ISA-3151
Measurement Channels Illuminance: 1ch
UV intensity: 1ch
Units of Measurement Illuminance: lx, Klx
UV intensity: mW/cm2
Measurement Range Illuminance: 0 lx to 130 Klx
UV Intensity: 0 to 30 mW/cm2
Units of Cumulative Measurement Cumulative Illuminance: lxh, Klxh, Mlxh
Cumulative amount of UV Light: mW/cm2, W/cm2
Display Range of Cumulative
Measurement
Illuminance: 0 lxh to 90 Mlxh
UV Intensity: 0 mW to 62 W/cm2h
Accuracy Illuminance: 10 lx to 100 Klx:±5 % [at 25°C, 50 %RH]
UV Intensity: 0.1 to 30 mW/cm2:±5 % [at 25°C, 50 %RH] (*2)
Relative Spectral Response Illuminance: Approximated to the CIE standard response function V (λ )
UV Intensity: 260 to 400 nm
Measurement Resolution Illuminance: Minimum of 0.01 lx
UV Intensity: Minimum of 0.001 mW/cm2
Responsiveness Response Time(90%):
3 sec. (at recording interval of 1 sec.)
6 sec. (at other intervals)
 
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*3) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
LCD Display Items Measurements, Battery Life Warning, etc.
 ・Measurements: Illuminance / UV Intensity / Temperature / Humidity / Cumulative Illuminance / Cumulative amount of UV Light
 ・Display Pattern: Alternating or Fixed display
 ・Display Digits: Up to 4 digits
Communication Interfaces Wireless Communication (Short Range Radio Communication)
 ・FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
 ・ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW)
USB Communication
Serial Communication (RS-232C)(*4)
Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
Power AA Alkaline Battery (LR6) x 1
Battery Life (*5) Approx. 4 months
Dimensions H 55 mm x W 78 mm x D 18 mm(excluding protrusions)
Antenna Length: 60 mm
Weight About 68 g (including battery, excluding sensor)
Operating Environment Temperature: -10 to 60 °C
Humidity: 90 %RH or less (no condensation)
Accessories AA alkaline battery (LR6), USB Communication Cable (US-15C), Illuminance/UV Sensor (ISA-3151), Temperature/Humidity Sensor (THA-3151 or HHA-3151), Software (CD-ROM), User's Manual Set (Warranty Included)
Compatible Base Units RTR-500, RTR-500NW/500AW, RTR-500DC
  • *1 When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
  • *2 Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
  • *3 Only "Endless" is available when using RTR-500W for Windows.
  • *4 For communication with the Data Collector RTR-500DC (Note: Optional serial communication cable TR-6C10 is required.
  • *5 Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.

Product RTR-576 RTR-576-H
Temperature/Humidity Sensor (External) THA-3001 HHA-3151(High-Precision Type)
Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance
Measurement Channels Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch
Measurement Range(*1) 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH
Accuracy ±0.5 °C ±5 %RH [at 25 °C, 50 %RH] ±0.3°C [at 10 to 50 °C]
±0.5°C [at all other temperatures]
±2.5 %RH [at 25 °C, 10 to 85 %RH]
±4.0 %RH [at 25 °C, 0 to 10 % or 85 to 99 %RH]
At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25.
Humidity Hysteresis: ±1.5 %RH or lower(*2)
Measurement Resolution 0.1 °C 1 %RH 0.1 °C 0.1 %RH
Responsiveness Response Time(90%):
Approx. 7 min.
Response Time(90%):
Approx. 7 min.
Response Time(90%):
Approx. 20 sec.
 
CO2 Sensor (Internal) NDIR
Measurement Channels CO2 Concentration 1ch
Measurement Range 0 to 9,999 ppm
Accuracy ±(50 ppm + 5 % of reading) [at 5,000 ppm or less] (*3)
Measurement Resolution Minimum of 1 ppm
Responsiveness Response Time (90%): Approx. 1 min.
 
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*4) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
LCD Display Items Measurements, Battery Level, etc.
- Measurements: CO2 concentration, Temperature or Humidity (fixed or alternating display)
Communication Interfaces Wireless Communication (Short Range Radio Communication)
FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz, RF Power: 7mW)
ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5mW) USB Communication Serial Communication (RS-232C) (*5)
Wireless Transmission Range Approx. 150 meters (500 ft) if direct and unobstructed
External Alarm Terminal (*6) Output Terminal: Open Drain Output (Voltage when OFF: DC less than 30V / Current when ON: less than 0.1A / Resistance when ON: about 15Ω)
Power AC Adaptor (AD-0638 or AD-06C1), AA Alkaline Battery (LR6) x 4
Battery Life (*7) Approx. 2 days (batteries only without AC adaptor)
Dimensions H 96 mm x W 66 mm x D 46 mm (excluding protrusions and sensor)
Antenna Length: 60 mm
Weight Approx. 220 g (including battery, excluding sensor)
Operating Environment Temperature: 0 to 45 °C
Humidity: 90 %RH or less (no condensation)
Accessories AA Alkaline Battery (LR6) x 4, AC Adaptor (AD-0638 or AD-06C1), USB Communication Cable (US-15C), Temperature/Humidity Sensor (THA-3001 or HHA-3151), User's Manual Set (Warranty Included)
Compatible Base Units RTR-500C, RTR-500NW/500AW, RTR-500DC
  • *1 Make sure to use the data logger within the operating environment as listed in the specifications.
  • *2 When used in environments where temperature and humidity are over the values of 50℃ 75%, 60℃ 50%, 70℃ 35%, and 80℃ 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
  • *3 Stated value is the measurement accuracy of the CO2 sensor when Auto Calibration is operating properly. A change in atmospheric pressure directly influences the reading of CO2, which can cause measurement errors; a decrease in pressure by 10hPa results in a relative decrease in CO2 by 1.6%. In such a case, we recommend carrying out the "Atmospheric Pressure Correction" function found in the software supplied with the Base Unit.
  • *4 Only "Endless" is available when using RTR-500W for Windows.
  • *5 For communication with the Data Collector RTR-500DC (Note: Optional serial communication cable TR-6C10 is required.)
  • *6 In order to use the external alarm terminal, please prepare a compatible connector: JST PAP-04V-S.
  • *7 Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
Dimensions
RTR-501 / 501L
RTR-501 / 501L Dimensions
1: Antenna
2: LCD Display
3: Optical communication Area
4: Back Case
5: Large Capacity Battery Case
RTR-502 / 502L
RTR-502 / 502L Dimensions
1: Antenna
2: LCD Display
3: Optical communication Area
4: Sensor Jack
5: Fluoropolymer-coated Electrical Wire
6: Thermistor
7: Back Case
8: Large Capacity Battery Case
RTR-503 / 503L
RTR-503 / 503L Dimensions
1: Antenna
2: LCD Display
3: Optical communication Area
4: Sensor Jack
5: Vinyl Chloride Coated Electrical Wire
6: Polypropylene Resin
7: Temperature/Humidity Sensor
8: Back Case
9: Large Capacity Battery Case
RTR-505 / 505L
RTR-505 / 505L Dimensions
1: Antenna
2: LCD Display
3: Optical communication Area
4: Sensor Jack
5: Back Case
6: Large Capacity Battery Case
RTR-507 / 507L
RTR-507 / 507L Dimensions
1: Antenna
2: LCD Display
3: Optical communication Area
4: Sensor Jack
5: Vinyl Chloride Coated Electrical Wire
6: Temperature/Humidity Sensor
7: Back Case
8: Large Capacity Battery Case
RTR-574
RTR-574 Dimensions
1: Antenna
2: Sensor Jack
3: POWER Button
4: LCD Display
5: DISPLAY Button
6: INTERVAL Button
7: REC/STOP Button
8: USB Communication Cable Jack
9: Illuminance Sensor Area
10: Ultraviolet Sensor Area
11: Temperature/Humidity Sensor Area
RTR-576
RTR-576 Dimensions
1.Antenna
2.Temperature/Humidity Sensor Area Jack
3.AC Adaptor Jack
4.CO2 Sensor (Internal)
5.LCD Display
6.DISPLAY Button
7.INTERVAL Button
8.REC/STOP Button
9.USB Communication Cable Jack
10.POWER Button
11.External Alarm Terminal (EXT ALM)
12.Temperature/Humidity Sensor Area