RTR-500 Series - Wireless Data Logging System

Standard Kit
  • Unit
    Unit
  • Lithium battery (inserted into a tube)
    Lithium battery  (inserted into a tube)
  • User's Manual
    User's Manual
  • Strap
    Strap
This Standard Kit is designed exclusively for: RTR-501, 501L, 502, 502L, 503, 503L, 505, 505L, 507,and 507L. See below for the RTR-574 and 576 Standard Kit.

Note:
Input modules have been gradually shifted from the black model to the white model.
RTR-501 / 501L
Standard Kit only
RTR-502 / 502L
Standard Kit + TR-5106
RTR-502 / 502L
RTR-503 / 503L
Standard Kit + TR-3310
RTR-503 / 503L
RTR-505-TC / 505-TCL
Standard Kit + Thermocouple Module (TCM-3010)
RTR-505-TC / 505-TCL
RTR-505-Pt / 505-PtL
Standard Kit + PT Module (PTM-3010)
RTR-505-Pt / 505-PtL
RTR-505-V / 505-VL
Standard Kit + Voltage Module (VIM-3010)
RTR-505-V / 505-VL
RTR-505-mA / 505-mAL
Standard Kit + 4-20mA Module (AIM-3010)
RTR-505-mA / 505-mAL
RTR-505-P / 505-PL
Standard Kit + Pulse Input Cable (PIC-3150)
RTR-505-P / 505-PL
RTR-507 / 507L
Standard Kit + HHB-3101
RTR-507 / 507L
Standard Kit for RTR-574 / 574-H
Standard Kit for RTR-574 / 574-H
Standard Kit for RTR-576 / 576-H
Standard Kit for RTR-576 / 576-H
Setup
RTR-500 Series setup
Optional Temperature Sensors for RTR-502/502L
TR-5101: Fluoropolymer Coated Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 80 sec. (in air)
Materials: (1)Thermistor, (4)Fluoropolymer Coated Electrical Wire
TR-5101: Fluoropolymer Coated Sensor
Unit: mm
TR-5106: Fluoropolymer Coated Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 80 sec. (in air) / Approx. 7 sec. (in agitated water)
Materials: (1)Thermistor
TR-5106: Fluoropolymer Coated Sensor
Unit: mm
TR-5220: Stainless Protection Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 150 sec. (in air) / Approx. 7 sec. (in agitated water)
Materials: (1)Thermistor, (2)Stainless pipe (SUS316), (3)Fluoropolymer Coated Compaction Tube, (4)Fluoropolymer Coated Electrical Wire
TR-5220: Stainless Protection Sensor
Unit: mm
TR-5320: Stainless Protection Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 90 sec. (in air) / Approx. 3 sec. (in agitated water)
Materials: (1)Thermistor, (2)Stainless pipe (SUS316), (3)Fluoropolymer Coated Compaction Tube, (4)Fluoropolymer Coated Electrical Wire
TR-5320: Stainless Protection Sensor
Unit: mm
TR-5420: Stainless Protection Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 90 sec. (in air) / Approx. 3 sec. (in agitated water)
Materials: (1)Thermistor, (2)Stainless pipe (SUS316), (3)Fluoropolymer Coated Compaction Tube, (4)Fluoropolymer Coated Electrical Wire
TR-5420: Stainless Protection Sensor
Unit: mm
TR-5530: Underwater Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Waterproof Capacity: Splash proof (Sensor and Cable)
Measurement Accuracy: Avg.±0.3°C(-20 to 80°C),Avg.±0.5°C(-40 to -20°C/80 to 110°C),Avg.±1.0°C(-60 to -40°C/110 to 155°C)
Response Time (90%): Approx. 150 sec. (in air) / Approx. 15 sec. (in agitated water)
Materials: (1)Thermistor, (4)Fluoropolymer Coated Electrical Wire, (5) Fluoropolymer Coated Mold
TR-5530: Underwater Sensor
Unit: mm
TR-5620:High Sensitivity Ultra-thin Sensor
Temperature Measurement Range: -60 to 155°C
Sensor Temperature Durability: -70 to 180°C
Measurement Accuracy: Avg.±0.5°C(-20 to 60°C),Avg.±1.0°C(-60 to -20°C/60 to 80°C),
Avg.±2.0°C(80 to 155°C)
Response Time (90%): Approx. 50 sec. (in air) / Approx. 1 sec. (in agitated water)
Materials: (1)Thermistor, (2)Stainless pipe (SUS316), (3)Fluoropolymer Coated Compaction Tube, (4)Fluoropolymer Coated Electrical Wire
TR-5620:High Sensitivity Ultra-thin Sensor
Unit: mm
TR-2C30: Sensor Extension Cable for RTR-502/502L
Note:
Only one extension cable per sensor. Using an extension cable may lead to measurement errors of +0.3°C at room temperature, and +0.5°C at -50°C

Waterproof Capacity: Splash proof
Materials: (1)Vinyl Chloride Coated Electrical Wire
TR-2C30: Sensor Extension Cable for RTR-502/502L
Unit: mm
Temperature / Humidity Sensor for RTR-503/503L
TR-3310
Cable Length: 1.0m
Possible Temperature Measurement Range: 0 to 55°C
Possible Humidity Measurement Range: 10 to 95%RH
Sensor Temperature Resistance: -10 to 60°C
Sensor Response Time: About 7 min. (90% response)
Temp Measurement Accuracy: Average +/-0.3°C
Humidity Measurement Accuracy: +/-5%RH (At 25°C, 50%RH)
Operational Conditions: Do not expose to condensation, dampness, corrosive gases or organic solvents.

The service life of humidity sensors can vary greatly depending on operating environment. Periodic calibration may be required.
Materials: (1)Temperature/Humidity sensor, (2) Polypropylene resin, (3) Vinyl Coated Electrical Wire
TR-3310
Unit: mm
Temperature / Humidity Sensor for RTR-507/507L
HHB-3101
Cable Length: 1.0m
Measurement Range: Temperature: -30 to 80°C, Humidity: 0 to 99 %RH
Sensor Temperature Durability:-30 to 80°C
Accuracy (Temperature):±0.3°C (at 0 to 50°C), ±0.5°C (at all other temperatures)
Accuracy (Humidity):±2.5%RH (at 25°C, 10 to 85 %RH), ±4 %RH (at 25°C, 0 to 10 % or 85 to 99 %RH)At temperatures other than 25°C and ≥ 0°C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower *1
Response Time (90%):Temperature: Approx. 7 min., Humidity: Approx. 20 sec.
Long Term Stability:±1%RH/yr, ±0.1°C/yr (under normal operational conditions) *2 *1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
*2: Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides for High Precision Temperature/Humidity Sensors).
Materials: (1) Temperature/Humidity sensor (2) Polycarbonate (3) Vinyl Chloride Coated Electrical Wire
HHB-3101
Unit: mm
TR-3C30: Sensor Extension Cable for RTR-507 / 507L
Note:
Only one extension cable per Temp/Humidity sensor.

Waterproof Capacity: Splash proof
(rated for use in daily life)
Temperature Durability: -25 to 60°C
Materials: (1) Vinyl Chloride Coated Electrical Wire
TR-3C30: Sensor Extension Cable for RTR-507 / 507L
Unit: mm
Input Module for RTR-505-TC
Note:
Input modules have been gradually phased from the black model to the white model. Both models provide the same measurement performance but differ in size; please see the figures below for the size of each model.
TCM-3010: Thermocouple Module
 
TCM-3010
Measurement Items Temperature
Compatible Sensors Thermocouple: Type K, J, T, S
Measurement Range -199 to 1700°C (within the sensor heat-durability range only)
Measurement Resolution Type K, J, T : 0.1°C
Type S : about 0.2°C
Measurement
Accuracy (*1)
Cold Junction
Compensation
At -40 to 10°C: ±0.5°C
At 10 to 40°C: ±0.3°C
At 40 to 80°C: ±0.5°C
Thermocouple
Measurement
Type K, J, T : ±0.3°C + 0.3% of reading
Type S : ±1°C + 0.3% of reading
Sensor Connection Miniature Thermocouple Connector (*2)
Operating Environment Temperature: -40 to 80°C , Humidity: 90%RH or less (no condensation)
(*1) Does not include inaccuracies of sensor actually connected.
(*2) Make sure to use a thermocouple sensor with a miniature thermocouple plug attached. T&D does not make available these plugs or sensors for sale.
Materials: (1)Polyamide, (2)Vinyl Coated Electrical Wire
TCM-3010: Thermocouple Module
Unit: mm
Input Module for RTR-505-Pt
Note:
Input modules have been gradually phased from the black model to the white model. Both models provide the same measurement performance but differ in size; please see the figures below for the size of each model.
PTM-3010: Pt Module
 
PTM-3010
Measurement Item Temperature
Compatible Sensors Pt100 (3-wire), Pt1000 (3-wire)
Measurement Range -199 to 600°C (within the sensor heat-durability range only)
Measurement Resolution 0.1°C
Measurement Accuracy (*1) Ambient Temperature of Input Module
At -40 to 10°C: ±0.5°C + 0.3% of reading
At 10 to 40°C: ±0.3°C + 0.3% of reading
At 40 to 80°C: ±0.5°C + 0.3% of reading
Sensor Connection Screw Clamp Terminal Block: 3-Terminal
Operating Environment Temperature: -40 to 80°C , Humidity: 90%RH or less (no condensation)
Accessories Protection Cover
(*1) Does not include inaccuracies of sensor actually connected.
Materials: (1)Polyamide, (2)Vinyl Coated Electrical Wire
PTM-3010: Pt Module
Unit: mm
Input Module for RTR-505-V
Note:
Input modules have been gradually shifted from the black model to the white model. Both models provide the same measurement performance but differ in size; please see the figures below for the size of each model.
VIM-3010: Voltage Module
 
VIM-3010
Measurement Item Voltage
Input Voltage Range 0 to 999.9mV, 0 to 22V Breakdown voltage: ±28V
Measurement Resolution 0 to 400mV: 0.1mV
400mV to 800mV: 0.2mV
800mV to 999mV: 0.4mV
999mV to 3.2V: 1mV
3.2V to 6.5V: 2mV
6.5V to 9.999V: 4mV
9.999V to 22V: 10mV
Measurement Accuracy Ambient Temperature of Input Module
At -40 to 10°C: ±1mV + 0.5% of reading
At 10 to 40°C: ±0.5mV + 0.3% of reading
At 40 to 80°C: ±1mV + 0.5% of reading
Input Impedance mV Range: About 3MΩ, V Range: About 1MΩ
Preheat Function Voltage Range (Preheating): 3V to 20V100mA, Time Range (Preheating): 1 to 999 seconds (in units of one-second)
Capacitor Load: 330µF or less(*1)
Sensor Connection Cable Insertion Connection: 4-Terminal
Compatible Wires Single wire: φ0.32 to φ0.65mm (AWG28 to AWG22), φ0.65mm (AWG22) recommended
Twisted wire: 0.32mm2 (AWG22), φ0.12mm or more in diameter
Strip length: 9 to 10mm
Operating Environment Temperature: -40 to 80°C , Humidity: 90%RH or less (no condensation)
(*1) For the previous version of VIM-3010 (Serial Numbers 08120001 - 08120A82, 08121000 - 0812113F): Capacitor load should be 220µF or less, Diode for backflow prevention built in the "Preheat OUT" side.
Materials: (1)Polyamide, (2)Vinyl Coated Electrical Wire
VIM-3010: Voltage Module
Unit: mm
Input Module for RTR-505-mA
Note:
Input modules have been gradually shifted from the black model to the white model. Both models provide the same measurement performance but differ in size; please see the figures below for the size of each model.
AIM-3010: 4-20mA Module
 
AIM-3010
Measurement Item 4-20mA
Input Current Range 0 to 20mA (Operational up to 40mA)
Measurement Resolution 0.01mA
Measurement Accuracy Ambient Temperature of Input Module
At -40 to 10°C: ±0.1mA + 0.3% of reading
At 10 to 40°C: ±0.05mA + 0.3% of reading
At 40 to 80°C: ±0.1mA + 0.3% of reading
Input Resistance 100Ω ±0.3Ω
Sensor Connection Cable Insertion Connection: Plus(+) 2 Parallel Terminals, Minus(-) 2 Parallel Terminals: Total 4 Terminals
Compatible Wires Single wire: φ0.32 to φ0.65mm (AWG28 to AWG22), φ0.65mm (AWG22) recommended
Twisted wire: 0.32mm2 (AWG22), φ0.12mm or more in diameter
Strip length: 9 to 10mm
Operating Environment Temperature: -40 to 80°C , Humidity: 90%RH or less (no condensation)
Materials: (1)Polyamide, (2)Vinyl Coated Electrical Wire
AIM-3010: 4-20mA Module
Unit: mm
Input Module for RTR-505-P
PIC-3150: Pulse Input Cable
 
PIC-3150
Measurement Item Pulse Number
Input Signal Non-voltage Contact Input
Voltage Input (0 to 27V) (Breakdown voltage: -5V, +27V)
Detection Voltage Lo: 0.5V or less, Hi: 2.5V or more
Chattering Filter ON (15Hz or less) / OFF (3.5kHz or less)
0-3V Rectangular Wave Signal
High Level Pulse Width Chattering Filter ON: 35ms or more,
Chattering Filter OFF: 180µs or more
Low Level Pulse Width Chattering Filter ON: 12ms or more,
Chattering Filter OFF: 100µs or more
Response Polarity Select either Lo→Hi or Hi→Lo
Maximum Count 61439 / Recording Interval
Input Impedance Approx. 100KΩ pull up
Max Jitter Normal: About 0.01 seconds, During Communication: About 0.1 seconds
Note that the specifications listed above are for the TR-55i-P/55i-PL being connected to this pulse input cable.
Materials: (1) M3.5 Crimp Terminal, (2) Vinyl Coated Electrical Wire
PIC-3150: Pulse Input Cable
Input Module Extension Cable for RTR-505
Note:
Only one extension cable per input module.
TR-3C30
Waterproof Capacity: Splash proof
(rated for use in daily life)
Temperature Durability: -25 to 60°C
Materials: (1) Vinyl Chloride Coated Electrical Wire
TR-3C30
Unit: mm
Sensors for RTR-574 / 576
THA-3001:Temperature/Humidity Sensor
 
THA-3001
Measurement Items Illuminance UV Intensity
Measurement Range 0 to 55°C 10 to 95%RH
Measuring Accuracy ±0.5°C ±5%RH (at 25°C and 50%RH)
Measurement Resolution 0.1°C
1%RH
Sensor Response Time Approx. 7 min. (90%)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents.
Materials: (1) Temp/Humidity Sensor (2) Polypropylene Resin
THA-3001:Temperature/Humidity Sensor
Unit: mm
THA-3151: Temperature/Humidity Sensor
 
THA-3151
Measurement Items Temperature Humidity
Measurement Range 0 to 55°C 10 to 95%RH
Measurement Resolution 0.1°C 1%RH
Measuring Accuracy Avg. ±0.3°C ±5%
(at 25°C and 50%RH)
Sensor Response
Time
About 7 min. (90%)
Humidity Hysteresis - ±1%RH (30 to 90%RH)
Operating
Environment
Temperature: 0 to 55°C
Humidity: 95%RH or less (no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H18 x W51.5 x D10 mm
Cable Length 1.5 m
Materials: (1)Polycarbonate (2)Vinyl chloride-shielded wire
THA-3151: Temperature/Humidity Sensor
Unit: mm
HHA-3151: Temperature/Humidity Sensor-High-Precision Type
Measurement Items Temperature Humidity
Measurement Range -30 to 80°C 0 to 99%RH
Measurement Resolution 0.1°C 0.1 %RH
Measurement Accuracy ±0.3°C (at 10 to 40 °C) ±0.5°C (at all other temperatures) ±2.5 %RH(at 25 °C, 10 to 85 %RH) ±4.0 %RH(at 25 °C, 0 to 10 % or 85 to 99 %RH) At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25.
Response Time (90%) Approx. 7 min. Approx. 20 sec.
Sensor Temperature Durability -30 to 80°C
Long Term Stability ±1%RH/yr, ±0.1°C/yr
Humidity Hysteresis - 1.5%RH or lower (*1)
Sensor Dimensions H 19 mm x W 65 mm x D 10 mm
Cable Length 1.5 m
Conditions for Use Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides for High Precision Temperature/Humidity Sensors).
*1: When used at temperatures equal to or higher than 0°C.
Materials: (1) Polycarbonate, (2)Vinyl chloride-shielded wire
HHA-3151: Temperature/Humidity Sensor-High-Precision Type
Unit: mm
ISA-3151: Illuminance UV Sensor ( for RTR-574 )
 
ISA-3151
Measurement Items Illuminance UV Intensity
Measurement Range 0 to 130,000lx 0 to 30mW/cm2
Measurement Resolution Minimum: 0.01 lx Minimum: 0.001 mW/cm2:
Measuring Accuracy 10 to 100,000 lx:
±5%(*1)
(at 25°C and 50%RH)
0.1 to 30 mW/cm2
±5%(*1)
(at 25°C and 50%RH)
Relative Spectral
Response
(*2) 260 to 400 nm
Cosine Correction
(cosΘ)
(*3) -
Operating
Environment
Temperature: -10 to 60°C
Humidity: 90%RH or less (no condensation)
Conditions for Use Do not expose to condensation, dampness, corrosive gases or organic solvents
Sensor Dimensions H23 x W65 x D12.6 mm
Cable Length 1.5 m
(*1) Compared to the value measured by the T&D standard sensor for calibration under our calibration light source.
(*2) Approximated to the CIE standard response function V (λ).
(*3) Within ±1.5% at 10°; Within ±3% at 30°; Within ±10% at 60°; Within ±30% at 80°
Materials: (1)Polycarbonate, (2)Glass, (3)Vinyl chloride-shielded wire
ISA-3151: Illuminance UV Sensor ( for RTR-574 )
Unit: mm
TR-1C30: Sensor Extension Cable for RTR-574 / 576
Up to 3 extension cables can be connected to one sensor (Temperature/Humidity Sensor THA-3151 and Illuminance UV Sensor ISA-3151).

Cable Length: 3 m
Temperature Durability: -25 to 60°C
Materials: Vinyl chloride-shielded wire
TR-1C30: Sensor Extension Cable for RTR-574 / 576
Unit: mm
Wall Attachment
TR-05K3 (for RTR-501/502/503)
(1)Lock screws, (2)Polycarbonate, (3)Double-sided Adhesive tape
Dimension (mm):
・ W66.6 x H70 x D24.7
・ Screw Holes: 2 - Φ4.2

Operational Environment Temp:
・ -40 to 80°C

*NOTE: Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
TR-05K3 (for RTR-501/502/503)
TR-05K3L (for RTR-501L/502L/503L)
(1)Lock screws (2)Polycarbonate (3)Double-sided Adhesive tape
Dimension (mm):
・ W66.6 x H70 x D51.7
・ Screw Holes: 2 - Φ4.2

Operational Environment Temp:
・ -40 to 80°C

*NOTE: Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
TR-05K3L (for RTR-501L/502L/503L)
TR-07K2 (for RTR-574)
Included:
・ Wall Mount Screws x 2
・ Double-Sided Adhesive Tape x 1
TR-07K2 (for RTR-574)
Unit: mm
AT-76K1 (for RTR-576)
Included:
・ Wall Mount Screws x 2
・ Double-Sided Adhesive Tape x 1
AT-76K1  (for RTR-576)
Others
TR-00P1: Maintenance Set (for RTR-501 / 502 / 503 / 505 / 507)
Contents:
・ Rubber Packing x 1
・ Silica Gel x 1
・ Double-sided Adhesive Tape x 1
・ Lock Screw x 2
TR-00P1: Maintenance Set (for RTR-501 / 502 / 503 / 505 / 507)
TR-11P2: Battery Set (for RTR-501 / 502 / 503 / 505 / 507)
Contents:
・ Lithium battery SAFT(LS14250) x 1
・ Tube x 1
・ Maintenance Set (TR-00P1) x 1
TR-11P2: Battery Set (for RTR-501 / 502 / 503 / 505 / 507)
RTR-500A1: External Power Adaptor Kit (for RTR-501 / 502 / 503 / 505 / 507)
Voltage Input: DC6V
Back-up Power: Ni-MH Battery (In case of power loss)
Back-up Time:About 4 days (*1)
Charging Method: Trickle Charge
Operating Temperature: 0 to 60°C
Waterproof Capacity: None
Weight: about 37g (without AC Adaptor)
Kit Contents:
・ External Power Adaptor x 1
・ AC Adaptor (AD-0638 or AD-06C1) x 1
・ Attachment hook x 1
・ Rubber Packing (small) x 1 (for AC Adaptor jack)
・ Maintenance Set (TR-00P1)

(*1)Varies depending on the amount of charge in the Ni-MH battery.
RTR-500A1: External Power Adaptor Kit (for RTR-501 / 502 / 503 / 505 / 507)
Unit: mm
RTR-500B1: Large Capacity Battery Kit (for RTR-501 / 502 / 503 / 505 / 507)
Power: Lithium Battery x 1 (LS26500) (*1)
Battery Life: about 4 years (*2)
Waterproof Capability: Splash proof
Operating Temperature: -40 to 80°C (*3)
Weight: about 75g (including Lithium Battery)
Kit Contents:
・ Large Capacity Battery Adaptor x 1
・ Attachment hook x 1
・ Maintenance Set (TR-00P1)

(*1) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
(*2) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
(*3) Operating temperature depends on the specifications for the data logger being used.
RTR-500B1: Large Capacity Battery Kit (for RTR-501 / 502 / 503 / 505 / 507)
Unit: mm
AD-0638: AC Adaptor (FCC) (for RTR-576)
Cable length: 1.8 meters
Input:AC100-240V
Output:DC6V 500mA
Frequency:50/60Hz
Plug Type: A
AD-0638: AC Adaptor (FCC) (for RTR-576)
AD-06C1: AC Adaptor (CE) (for RTR-576)
Cable length: 1.8 meters
Input:AC100-240V
Output:DC6V 1A
Frequency:50/60Hz
Plug Type: C
AD-06C1: AC Adaptor (CE) (for RTR-576)
US-15C: USB Communication Cable (for RTR-574 / 576)
Cable Length: 1.5 m
US-15C: USB Communication Cable (for RTR-574 / 576)
Unit: mm